Showing results: 46 - 60 of 831 items found.
-
Guangdong Bell Experiment Equipment Co.,Ltd
Battery Crush Test Equipment(Horizontal)Application: Battery Module / Battery Pack / Battery System crush test, penetration test.Drive Mode: Electro-hydraulic ServoCrush Tool: Semi-cylinder, hemisphere (According to test standard)
-
Guangdong Bell Experiment Equipment Co.,Ltd
All industrial battery tester from BELL lithium battery test chamber supplier meet the standards of GB31467.3, ECE-R100 and UL2580. The tests mainly simulating all the condition that driving an EV meet, including battery crush test, battery drop test, flammable test, temperature cycle test, short circuit test, thermal test, explosion test, and environmental test, etc.
-
Xiamen WinAck Battery Technology Co., Ltd.
This battery PCM/PCB test equipment is suitable for the basic parameter test and protection function test of lithium battery pack protection board of mobile phone & digital products; it is also used for downloading, comparing and PCB calibration of battery management.
-
Keysight Technologies
The VoLTE Battery Test, Reference Solution is a fully automated test solution for chipset vendors and device makers who need to follow operators’ VoLTE battery acceptance test plans.
-
TOB-BTS-15V6A -
Xiamen Tob New Energy Technology Co., Ltd
8 Channels 15V6A Battery Pack Test System Laptop Battery Performance Testing. TOB-BTS-15V6A Battery tester equipment is an eight-channel battery analyzer to analyze polymer battery and cylindrical batteries from 12 mA to 6000 mA, up to 15V.
-
-
-
17040 -
Chroma Systems Solutions, Inc.
The 17040 Regenerative Battery Pack Test System is a high precision system specifically designed for secondary battery module and battery pack test. It has an energy regenerative function to greatly reduce power consumption during discharge, and ensure a stable power grid without generating harmonic pollution on other devices – even in dynamic charge and discharge conditions. It is capable of recycling the energy discharged by the battery pack test back to the grid reducing wasted energy that traditional equipment discharges in the form of heat.
-
EP1150A -
Keysight Technologies
PathWave Lab Operations for Battery Test enables efficient planning and coordination of your entire battery test laboratory. It manages all resources, including test fields, test systems, and your device under test (DUT). PathWave provides an integrated, web-based lab management platform that helps you modernize your test workflows, eliminating legacy paper-based processes, and increasing data integrity and traceability.
-
WA-BMS-3NE -
Xiamen WinAck Battery Technology Co., Ltd.
The battery BMS test system can be applied to the integrated test of 1S~100S power lithium-ionbattery pack BMS with LMU and BMCU modules, such as the BMS performance andHILL test.
-
Bloomy Controls, Inc.
The Mixed-Signal Battery-Test System is an automated test platform designed to meet today’s advanced battery test requirements. The platform is ideal for testing a range of battery cells and packs, and can be used in applications such as research and design, quality control, and end-of-line manufacturing. Its distributed architecture provides a scalable solution with configurable system components to accommodate specific applications.
-
17020 -
Chroma ATE Inc.
Chroma's 17020 is a high precision system specifically designed for secondary battery modules and pack tests. Accurate sources and measurements ensure the test quality that is suitable to perform repetitive and reliable tests that are crucial for battery modules / packs, for both incoming or outgoing inspections as well as capacity, performance, production and qualification testing. Chroma's 17020 system architecture offers regenerative discharge designed to recycle the electric energy sourced by the battery module ei ther back to the channel s in the sys tem performing a charging function or to the utility mains in the most energy efficient manner. This feature saves electricity, reduces the facilities thermal foot print and provides a green solution by reducing the environmental impact on our planet. Chroma's 17020 system is equipped with multiple independent channels to support dedicated charge / discharge tests, on multiple battery modules / packs, each with discrete test characteristics. The channels can easily be paralleled to support higher current requirements. This feature provides the ultimate flexibility between high channel count and high current testing.
-
9841 -
PRODIGIT Electronics Co, Ltd.
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
706 -
Electronic Specialties Inc.
Controlled by microprocessor, simply activate the switch once and the #706 applies a precisely timed, 10 second load to the battery. The test results, “OK”,“WEAK” or ”BAD” are then displayed along with the test voltage, until the unit is disconnected. The #706 also tests charging voltage and relative starter current draw.
-
Guangdong Bell Experiment Equipment Co.,Ltd
DGBell's Battery Pack Rotate Test Device Single storage cell safety testTest object: Battery storage pack or systemRotate the battery pack 360°around X axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Rotate the batter pack 360°around Y axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Accept standard: Battery pack or system has no electrolyte leakage, no rupture at case, no fire nor explosion. And remain the connection reliable, the structure intact, the insulation resistance value not less than 100 Omega /v.